Micromachined Ultrasound Integrated Circuit

,
,

Keywords: , , , ,

we present the design and experimental acoustic test data for an ultrasound transducer technology based on a combination of micromachined dome-shaped piezoelectric resonators arranged in a flexible architecture. Our high performance niobium-doped lead zirconate titanate film is implemented in three-dimensional dome-shaped structures, which form the basic resonating cells. Adjustable frequency response is realized by mixing these basic cells and modifying their dimensions by lithography. Improved characteristics such as high sensitivity, adjustable wide-bandwidth frequency response, low transmit voltage compatible with ordinary integrated circuitry, low electrical impedance well matched to coaxial cabling, and intrinsic acoustic impedance match to water are demonstrated.

PDF of paper:


Journal: TechConnect Briefs
Volume: 2, Nanotechnology 2013: Electronics, Devices, Fabrication, MEMS, Fluidics and Computational (Volume 2)
Published: May 12, 2013
Pages: 181 - 184
Industry sector: Sensors, MEMS, Electronics
Topic: MEMS & NEMS Devices, Modeling & Applications